Distal femur fractures are traumatic injuries involving the region extending from the distal metaphyseal-diaphyseal junction to the articular surface of the femoral condyles. Minimally-Invasive and Mesh Calcaneus Plating System features two distinct and anatomically contoured plate designs that address a variety of calcaneus fractures, while meeting the stress requirements present in the trabecular anatomy of the calcaneus. 3-Hole Extended, These two new plate designs expand upon Zimmer Biomets 9500 Euclid Avenue, Cleveland, Ohio 44195 |, Important Updates + Notice of Vendor Data Event, (https://orthoinfo.aaos.org/en/diseases--conditions/patellar-kneecap-fractures/), Visitation, mask requirements and COVID-19 information, Non-steroidal anti-inflammatory drugs (NSAIDs). Minimally-Invasive and Mesh Calcaneus Plating System These cookies do not store any personal information. The purpose of this study was to determine if a tension band constructed of FiberWire (Arthrex, Naples, FL), a high-strength polyester and polyethylene suture, will provide fixation that is equivalent to an 18-gauge metal wire tension band. Medial Border Plate features two distinct and anatomically contoured plate designs that spanning the comminuted anterior process of the calcaneus. Dr. Adam Schiff demonstrates a Metatarsal Fracture procedure using VariAx fracture plates. 24515 Open treatment of humeral shaft fracture with plate/screws, with or without cerclage 24516 Treatment of humeral shaft fracture, with insertion of intramedullary implant, with or without cerclage and/or locking screws 24545 Open treatment of humeral supracondylar or transcondylar fracture, includes internal fixation, It can be used to repair a high ankle sprain, which damages the soft tissue structures between the tibia and fibula and causes these bones to separate. and treatment algorithm for patella fractures, including recent advancements in surgical technique to optimize outcomes and minimize complications. Solving complicated fractures with simple innovative solutions - Plating that fits. Ankle Fracture Plating System, CHARLOTTE A fracture arises when the load-bearing capacity of a bone is exceeded by forces applied to it, for example during trauma. They may also be able to feel the edges of the fractured bone pieces through your skin. 2 Arthrex mesh plates can be used in conjunction with this set for fixation of these frequently challenging injuries. The 4.0 mm blunt-tipped cannulated screws were designed specifically for patella fractures. Fragility fractures are the clinical outcome of osteoporosis. Some fractures require surgery to repair. addition to these locking screw designs, a cobalt chrome3.5 mm that require plate strength and the ability to insert screws around hole as shown in the illustration below. Functional outcomes of revision osteosynthesis after failure of surgical treatment of patellar fractures. The procedure uses a Stryker Asnis III 4.0mm cannulated screw and a VariAx Foot oblique t-plate. Compared to traditional K-wires, this construct has been shown to be stronger.1. An injury that might cause a joint sprain for an adult can cause a growth plate fracture in a child. System Surgical Technique, These two new plate designs expand upon Zimmer Patella fracture is commonly caused by either direct trauma (e.g. ecosystems across the episode of care. Make sure to follow through with physical therapy after your fracture has healed, in order to restore your muscle strength and range-of-motion. If you think you can, but it is still painful, its probably best not to try until you have been diagnosed. All plates are made of titanium and have a low-profile thickness of 1.6 mm with screws sitting flush on the plate. The distinct andsimple-to-use carbon fiber targeting guides (small K-wire fixation with metal tension band were used for fixation in 315 (70%) patients and cannulated screws were used with tension band for fixation in 133 (30%). Lisfranc Reconstruction System, Coding, coverage and reimbursement information. compromise as can be seen in the below views.. Permanent loss of motion in your knee, especially in its ability to bend and extend. Practical guidelines for the treatment of patellar fractures in adults. Current accepted surgical options. The An individual who has sustained a patella fracture usually presents with pain in the affected knee. provide both strength to the inner area of the plate, and Designed with the surgeon in mind, the plates have many features to help create a more reproducible procedure: The locking straight plates include a slide hole, which allows slight movement across the fracture line to facilitate the best plate placement. designed to be bent or altered by the surgeon. Stainless Steel, Type I Anodized titanium, and machined These Indications for operative treatment of a patella fracture include the following: Disruption of the extensor mechanism Articular incongruity with more than 2 mm of stepoff More than 3 mm of. Policy. Screw System - Quick and Easy Screw Fixation with the Low Profile Snap-off Screw - LS0451, Trim-It Drill Pin - The need to remove hardware is disappearing - LS0441, Arthrex Knotless TightRope - LS2-0426-EN, Arthrex Power System 600 - Quality you can trust, Performance you can count on - LS2-0600-EN, Trim-It Drill Pin All-Inside Technique - LS1-0443-EN, ArthroBrostrom The Only Arthroscopic Ankle Ligament Repair Kit - LS1-0490-EN, Freedom in Anatomic Femoral Socket Placement - LS0187, Quantified Precision with the T3 AMZ System - Tibial Tuberosity Transfer with Anteromedialization - LS0145, Percutaneous Glenohumeral Repair with SutureTak Implants - LS0508, Collagen Coated FiberWire Suture - LS1-0235-EN, InternalBrace? 8,9 At our Level 1 trauma center, 1 fellowship-trained trauma surgeon treats all operative patella fractures with a low profile anterior mesh plate. This construct has been shown to be stronger than the traditional K-wire with cerclage wire constructs.1. Wright PB, Kosmopoulos V, Cot RE, Tayag TJ, Nana AD. It includes 4.0 mm blunttipped cannulated screws that, when used in conjunction with FiberTape as an anterior tension band, creates a. A vision requires leadership to become reality. These can include: Patella fractures are not common, but traumatic injuries do happen. A patella fracture can be simple or complex. the calcaneus will allow good plate/bone apposition. All plates are made of titanium and have a low-profile thickness of 1.6 mm with screws sitting flush on the plate. These anatomically contoured plates are not Plate breakage is one form of construct failure after a clavicle fracture treated with an open reduction and plate fixation. Arthrex is the first company to obtain FDA clearance for plating in patella fracture indications. Get useful, helpful and relevant health + wellness information. 3). The report includes a detailed description and tips of the surgical technique. The quadriceps and patellar tendon attach to your patella, which normally allows you to flex and extend your knee. a locking calcaneus plate design that address comminuted fractures The demonstration is performed by Dr. Donald Bohay and John Anderson of Grand Rapids, MI. In the largest series to date, Hoshino reported on 448 patella fractures treated surgically. counseling information, see the package insert or contact your local Fracture of the patella is a common injury among adults having higher prevalence among males population. angulation) off center. This video demonstrates a medial column fusion. Then theyll examine your knee. Please confirm you are a healthcare professional. In addition to the new OrthoLine fracture plates, the fracture management system includes a variety of screw options, including fully threaded headless compression screws, partially threaded screws, cannulated lag screws, low-profile screws, and QuickFix cannulated screws. P atella fracture is a common injury seen in all age groups and accounts for approximately 1% of all fractures. Proximal Humerus Fracture Repair with Arthrex SuturePlate Arthrex 76.8K subscribers Subscribe 353 Share 69K views 6 years ago Show more Show more Comments are turned off. Dr. Adam Schiff demonstrates a Fifth Metatarsal procedure using VariAx fracture plates. Most people will be feeling good in about six weeks, and able to return to all of their normal activities within three to six months. The Patella Fracture Set was specifically designed to address common obstacles (eg, amount of comminution, degree of osteoporosis, and natural forces across the patella) and to facilitate fixation of challenging injuries. A patella fracture is a break in your kneecap the small, flat bone that covers and protects your knee joint like a shield. They might have you try to extend your leg. Calcaneus plates, and are designed to address comminuted fractures 3 drill holes from inferior pole to superior pole of patella with 2.0mm drill. February 27, 2023 By scottish gaelic translator By scottish gaelic translator Suture holes in the plate can be optionally used for soft-tissue reattachment or ligament bracing. Patellar stability and osteosynthesis rates have been shown to improve significantly with locked plates. #2 to #5 non-absorbable suture Krakow stitches x2 into tendon (4 strands exiting tendon) suture passer from superior to inferior to pass suture ends. Patella Fractures are traumatic knee injuries caused by direct trauma or rapid contracture of the quadriceps with a flexed knee that can lead to loss of the extensor mechanism. The mesh plates combine an MIS plate design with Patented SmartLock polyaxial locking technology 1. Anatomic screw trajectories are designed to Plates -Ti-6Al-4V ELI,Type 2 Anodized Titanium Alloy. If you cant, that will likely necessitate surgical intervention. 2023 Arthrex, Inc. All rights reserved. All other trademarks are trademarks of their respective owners or holders. The adaptability design allows for modularity and variable angles, you can base screw positoning on your patient at hand, not a plate's pre-existing design. The patella has a thick layer of cartilage, which can be injured in the break. The targeting guides arerigid for representative; search this website for additional product Learn more Don't. Screw trajectories Certain products may not be approved for sale in all countries. the plate will alter targeting guide alignment. The patello-femoral joint is biomechanically very stressed when the knee is loaded. It can also be used to stabilize a fracture of the fibula. cpt code for lateral column lengthening. existing non-locking perimeter plate and the A.L.P.S. patient-reported feedback to facilitate care, outcomes and But opting out of some of these cookies may have an effect on your browsing experience. With anatomically contoured plates designed or validated using our proprietary SOMA technology, streamlined instrumentation, and trained representatives, our plating portfolio is designed with you in mind. Patella fracture fixation remains a significant challenge for orthopedic surgeons. The history reveals a direct blow to the knee, a fall, or a combination of the two. Patella fractures can cause the extensor mechanism of your knee to no longer function properly. sinus tarsi approach. extended 2-Hole, large extended 2-Hole, and large extended 3-Hole With a 1.6-mm low profile and flush-sitting Liked by Jessica Maquet, LAT, ATC Quadrupled semitendinosus-gracilis autograft fixation in the femoral tunnel: a comparison between a metal and a bioabsorbable interference screw The patella is then inverted to permit direct visualization of fracture fragments and the articular surface 33 ( Fig. You also have the option to opt-out of these cookies. and large) are designed toaccurately target the Some patella fractures are simple, but this small bone is also capable of breaking into many pieces. Recovery can be long, and side effects are common. (IFU) for full prescribing and risk information, please call 1-800-348-2759, press 4 for 411 Technical Support., 1. Data on File at Biomet. In addition, FiberTape. Mller EC, Frosch KH. A patellar fracture is a break in your kneecap. Radiological studies revealed right distal radial fracture in two locations. In addition, FiberTape suture has been attached to 5 in needles designed to pass through the screws, subsequently allowing for its use as a tension band. locking were among the first to report on locking plates for patella fractures [24,25,26, 33, 34]. This set includes 4.0 mm blunt-tip cannulated lag screws, which feature smooth tips to help avoid cutting suture, and a specially designed 5-in needle for easily passing suture through the screws to create tension-band fixation. The aim of the PSCG is to dene the PSCG is anatomical. In addition, the anterior F.A.S.T. The anatomically contoured plate is designed to replicate the patient's specific scapular anatomy, thereby resulting in a more secure reconstruction of severely displaced fractures. Patella fractures represent approximately 1% of all fractures and present in a variety of patterns, which can make osteosynthesis challenging. 25608-RT (Open fracture repair was performed of the distal radius. Meanwhile, its very important to be patient and committed to the healing process. Coming to a Cleveland Clinic location?Hillcrest Cancer Center check-in changesCole Eye entrance closingVisitation, mask requirements and COVID-19 information, Notice of Intelligent Business Solutions data eventLearn more. 5th Metatarsal Fracture System Uniquely designed screw and plate system to treat complex 5th metatarsal fractures. A patella fracture is usually caused by a direct impact to your knee. Incision is made, distal radius is identified, manipulated into place, and two pins across both fragments to maintain alignment. correspond to the complicated anatomy of the calcaneus. Your healthcare provider will ask about your symptoms and what happened at the time of the injury. Your orthopaedic surgeon will let you know how much you can bend your knee. Dr. Adam Schiff demonstrates a First tarsometatarsal joint fixation procedures using VariAx fracture plates. Arthrex, Naples, FL, USA) is a novel locking plate, which addresses the aforementioned limitations. Abstract. Arthrex 2 years 10 months Shoulder Consultant Arthrex Jul 2018 - Feb 2020 1 year 8 months. MIS plates are designed to meet the needs of a variety of locking Simplicity and adaptability with seven new indication specific plates using the comprehensive locking and non-locking screw system. . Any compromise of the joint surface is likely to lead to degenerative joint disease. This site is for visitors from the United States. Patella Fracture Repair with Patella SuturePlate Arthrex Europe 539 subscribers Subscribe 24 Save 6.3K views 5 years ago .more .more Notice Age-restricted video (based on Community. Distribution to any other recipient is prohibited., For product information, including indications, contraindications, The mechanism of injury . calcaneus plateportfolio therefore providing comprehensive plating 1, 2 In total, 70% to 90% of patella fractures are transverse, with most. It is, therefore, highly desirable, in patellar fractures to strive for anatomical reduction of the joint surface and stable fixation. Abstract and Figures Transverse patella fractures with loss of knee extensor mechanism function are a common orthopaedic injury requiring operative fixation. Out of these cookies, the cookies that are categorized as necessary are stored on your browser as they are as essential for the working of basic functionalities of the website. To prevent disruption of the medially based vascular supply to the patella,34 a lateral parapatellar arthrotomy is then performed, fracture hematoma is evacuated, and the knee joint is irrigated. wide range of plate sizing options for a variety of patient anatomies. Solving complicated fractures with simple innovative solutions Plating that fits. All other trademarks are trademarks of their respective owners or holders. Case series of patellar plating have been reported, 7 and biomechanical studies have shown equivalent or superior results with plate fixation as compared to tension banding. A short arm cast is applied. It covers the incision, the desired outcome, the osteotomy and fixation. Licensed from Prof. D. Wolter, Hamburg, GermanyStryker Corporation or its divisions or other corporate affiliated entities own, use or have applied for the following trademarks or service marks: Anchorage, Stryker, VariAx. Palpable patellar defect (a change in your kneecap that you can feel through your skin). Arthrex is the first company to obtain FDA clearance for plating in patella fracture indications. This plate functions similarly to a one-third tubular plate but is more contoured and includes a distal cluster of 2.7 mm hexalobe screws to capture fragments in cases with distal comminution. Principles. Watch to help you deliver support and guidance to your . Plate fixation of patella fractures is a method that allows for more rigid stabilization and earlier mobilization. trajectory of the screw hole may not be ideal. ORTHOLOC Straight Plate Broad, Titanium, 1.6 mm, 5 Hole, Straight Plate Broad, Titanium, 1.6 mm, 6 Hole, Straight Plate Broad, Titanium, 1.6 mm, 7 Hole, Straight Plate Broad, Titanium, 1.6 mm, 8 Hole, Straight Plate Broad, Titanium, 1.6 mm, 9 Hole, Straight Plate Broad, Titanium, 1.6 mm, 10 Hole, T-Plate, Titanium, 1.6 mm, 2-Hole / 3-Hole, T-Plate Broad, Titanium, 1.6 mm, 2-Hole / 3-Hole, T-Plate Broad, Titanium, 1.6 mm, 3-Hole / 4-Hole, Low-Profile Cortical Screw, Titanium, 1.6 X 6 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 7 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 8 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 9 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 10 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 11 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 12 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 13 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 14 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 16 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 18 mm, Low-Profile Cortical Screw, Titanium, 1.6 X 20 mm, Low-Profile VAL Screw, Titanium, 1.6 X 6 mm, Low-Profile VAL Screw, Titanium, 1.6 X 7 mm, Low-Profile VAL Screw, Titanium, 1.6 X 8 mm, Low-Profile VAL Screw, Titanium, 1.6 X 9 mm, Low-Profile VAL Screw, Titanium, 1.6 X 10 mm, Low-Profile VAL Screw, Titanium, 1.6 X 11 mm, Low-Profile VAL Screw, Titanium, 1.6 X 12 mm, Low-Profile VAL Screw, Titanium, 1.6 X 13 mm, Low-Profile VAL Screw, Titanium, 1.6 X 14 mm, Low-Profile VAL Screw, Titanium, 1.6 X 16 mm, Low-Profile VAL Screw, Titanium, 1.6 X 18 mm, Low-Profile VAL Screw, Titanium, 1.6 X 20 mm, Straight Plate, Titanium, 2.0 mm, 10 Hole, Straight Plate, Titanium, 2.0 mm, 11 Hole, Straight Plate, Titanium, 2.0 mm, 12 Hole, Straight Plate, Titanium, 2.0 mm, 13 Hole, Straight Plate, Titanium, 2.0 mm, 14 Hole, Straight Plate, Titanium, 2.0 mm, 15 Hole, T-Plate, Titanium, 2.0 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 2.0 mm, 3-Hole / 4-Hole, Low-Profile VAL Screw, Titanium, 2.0 X 6 mm, Low-Profile VAL Screw, Titanium, 2.0 X 7 mm, Low-Profile VAL Screw, Titanium, 2.0 X 8 mm, Low-Profile VAL Screw, Titanium, 2.0 X 9 mm, Low-Profile VAL Screw, Titanium, 2.0 X 10 mm, Low-Profile VAL Screw, Titanium, 2.0 X 11 mm, Low-Profile VAL Screw, Titanium, 2.0 X 12 mm, Low-Profile VAL Screw, Titanium, 2.0 X 13 mm, Low-Profile VAL Screw, Titanium, 2.0 X 14 mm, Low-Profile VAL Screw, Titanium, 2.0 X 16 mm, Low-Profile VAL Screw, Titanium, 2.0 X 18 mm, Low-Profile VAL Screw, Titanium, 2.0 X 20 mm, Low-Profile VAL Screw, Titanium, 2.0 X 22 mm, Low-Profile VAL Screw, Titanium, 2.0 X 24 mm, Low-Profile VAL Screw, Titanium, 2.0 X 26 mm, Low-Profile VAL Screw, Titanium, 2.0 X 28 mm, Low-Profile VAL Screw, Titanium, 2.0 X 30 mm, Straight Plate, Titanium, 2.4 mm, 10 Hole, Straight Plate, Titanium, 2.4 mm, 11 Hole, Straight Plate, Titanium, 2.4 mm, 12 Hole, Straight Plate, Titanium, 2.4 mm, 13 Hole, Straight Plate, Titanium, 2.4 mm, 14 Hole, Straight Plate, Titanium, 2.4 mm, 15 Hole, T-Plate, Titanium, 2.4 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 2.4 mm, 3-Hole / 4-Hole, Low-Profile VAL Screw, Titanium, 2.4 X 8 mm, Low-Profile VAL Screw, Titanium, 2.4 X 9 mm, Low-Profile VAL Screw, Titanium, 2.4 x10 mm, Low-Profile VAL Screw, Titanium, 2.4 X 11 mm, Low-Profile VAL Screw, Titanium, 2.4 X 12 mm, Low-Profile VAL Screw, Titanium, 2.4 X 13 mm, Low-Profile VAL Screw, Titanium, 2.4 X 14 mm, Low-Profile VAL Screw, Titanium, 2.4 X 16 mm,Low-Profile VAL Screw, Titanium, 2.4 X 16 mm, Low-Profile VAL Screw, Titanium, 2.4 X 18 mm, Low-Profile VAL Screw, Titanium, 2.4 X 20 mm, Low-Profile VAL Screw, Titanium, 2.4 X 22 mm, Low-Profile VAL Screw, Titanium, 2.4 X 24 mm, Low-Profile VAL Screw, Titanium, 2.4 X 26 mm, Low-Profile VAL Screw, Titanium, 2.4 X 28 mm, Low-Profile VAL Screw, Titanium, 2.4 X 30 mm, Straight Plate, Titanium, 3.0 mm, 10 Hole, Straight Plate, Titanium, 3.0 mm, 11 Hole, Straight Plate, Titanium, 3.0 mm, 12 Hole, Straight Plate, Titanium, 3.0 mm, 13 Hole, Straight Plate, Titanium, 3.0 mm, 14 Hole, Straight Plate, Titanium, 3.0 mm, 15 Hole, T-Plate, Titanium, 3.0 mm, 2-Hole / 4-Hole, T-Plate, Titanium, 3.0 mm, 3-Hole / 4-Hole, Low-Profile Cortical Screw, Titanium, 3.0 X 8 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 10 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 12 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 14 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 16 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 18 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 20 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 22 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 24 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 26 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 28 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 30 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 32 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 34 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 36 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 38 mm, Low-Profile Cortical Screw, Titanium, 3.0 X 40 mm, Low-Profile Locking Screw, Titanium, 3.0 X 8 mm, Low-Profile Locking Screw, Titanium, 3.0 X 10 mm, Low-Profile Locking Screw, Titanium, 3.0 X 12 mm, Low-Profile Locking Screw, Titanium, 3.0 X 14 mm, Low-Profile Locking Screw, Titanium, 3.0 X 16 mm, Low-Profile Locking Screw, Titanium, 3.0 X 18 mm, Low-Profile Locking Screw, Titanium, 3.0 X 20 mm, Low-Profile Locking Screw, Titanium, 3.0 X 22 mm, Low-Profile Locking Screw, Titanium, 3.0 X 24 mm, Low-Profile Locking Screw, Titanium, 3.0 X 26 mm, Low-Profile Locking Screw, Titanium, 3.0 X 28 mm, Low-Profile Locking Screw, Titanium, 3.0 X 30 mm, Low-Profile Locking Screw, Titanium, 3.0 X 32 mm, Low-Profile Locking Screw, Titanium, 3.0 X 34 mm, Low-Profile Locking Screw, Titanium, 3.0 X 36 mm, Low-Profile Locking Screw, Titanium, 3.0 X 38 mm, Low-Profile Locking Screw, Titanium, 3.0 X 40 mm, Low-Profile VAL Screw, Titanium, 3.0 X 8 mm, Low-Profile VAL Screw, Titanium, 3.0 X 10 mm, Low-Profile VAL Screw, Titanium, 3.0 X 12 mm, Low-Profile VAL Screw, Titanium, 3.0 X 14 mm, Low-Profile VAL Screw, Titanium, 3.0 X 16 mm, Low-Profile VAL Screw, Titanium, 3.0 X 18 mm,Low-Profile VAL Screw, Titanium, 3.0 X 18 mm, Low-Profile VAL Screw, Titanium, 3.0 X 20 mm, Low-Profile VAL Screw, Titanium, 3.0 X 22 mm, Low-Profile VAL Screw, Titanium, 3.0 X 24 mm, Low-Profile VAL Screw, Titanium, 3.0 X 26 mm, Low-Profile VAL Screw, Titanium, 3.0 X 28 mm, Low-Profile VAL Screw, Titanium, 3.0 X 30 mm,Low-Profile VAL Screw, Titanium, 3.0 X 30 mm, Low-Profile VAL Screw, Titanium, 3.0 X 32 mm, Low-Profile VAL Screw, Titanium, 3.0 X 34 mm, Low-Profile VAL Screw, Titanium, 3.0 X 36 mm, Low-Profile VAL Screw, Titanium, 3.0 X 38 mm, Low-Profile VAL Screw, Titanium, 3.0 X 40 mm, Low-Profile Locking Screw, SS, 4.0 X 18 mm, Low-Profile Locking Screw, SS, 4.0 X 20 mm, Low-Profile Locking Screw, SS, 4.0 X 22 mm, Low-Profile Locking Screw, SS, 4.0 X 24 mm, Low-Profile Locking Screw, SS, 4.0 X 26 mm, Low-Profile Locking Screw, SS, 4.0 X 28 mm, Low-Profile Locking Screw, SS, 4.0 X 30 mm, Low-Profile Locking Screw, SS, 4.0 X 32 mm, Low-Profile Locking Screw, SS, 4.0 X 34 mm, Low-Profile Locking Screw, SS, 4.0 X 36 mm, Low-Profile Locking Screw, SS, 4.0 X 38 mm, Low-Profile Locking Screw, SS, 4.0 X 40 mm, Low-Profile Locking Screw, SS, 4.0 X 42 mm, Low-Profile Locking Screw, SS, 4.0 X 44 mm, Low-Profile Locking Screw, SS, 4.0 X 46 mm, Low-Profile Locking Screw, SS, 4.0 X 48 mm, Low-Profile Locking Screw, SS, 4.0 X 50 mm, Low-Profile Locking Screw, SS, 4.0 X 52 mm, Low-Profile Locking Screw, SS, 4.0 X 54 mm, Low-Profile Locking Screw, SS, 4.0 X 56 mm, Low-Profile Locking Screw, SS, 4.0 X 58 mm, Low-Profile Locking Screw, SS 4.0 X 60 mm, Low-Profile Locking Screw, SS 4.0 X 65 mm, Guidewire with Trocar Tip, 1.1 mm X 150 mm, Depth Device, 2.7/ 3.5/ 4.0 mm, Low Profile, Vet, Screw Holding Forceps, Self-Retaining, Vet, General OrthoLine Sterilization Case Insert, 1.6 mm and Broad 1.6 mm OrthoLine Plates and Screws, 3.5 mm and Broad 3.5 mm/4.0 mm OrthoLine Plates and Screws, OrthoLine Disposables and Limited Reusables, OrthoLine Distal Humeral Fracture System: Canine Elbow Procedure Demonstration, OrthoLine Distal Humeral Fracture System: Sawbone Application on a Canine Elbow Procedure Demonstration, OrthoLine Fracture Management System: Sawbone Application on a Canine Tibia, OrthoLine Distal Humeral Fracture System, OrthoLine Small Animal Fracture Straight Plate, OrthoLine Fracture Management System: Design Features, OrthoLine Distal Humeral Fracture Management System Weight Reference Chart, OrthoLine Fracture Management System: Weight Reference Chart, Inventory Control Form: 3.5 mm Fracture Plates and Screws, Inventory Control Form: 3.0 mm Fracture Plates and Screws, Inventory Control Form: 1.6 mm Fracture Plates and Screws, OrthoLine Universal Plating System: Clinical Case Series II, OrthoLine Fracture Management System: Clinical Case Series, OrthoLine Fracture Management System: Biomechanics, Standing Room Only: Veterinary WebInHourOrthoLine System Overview, Cortical/locking/variable-angle locking screws, Indicated for sizes from small cats to large dogs, Presenter: Sean M. Murphy, DVM, DACVS, Presenter: Mark Rochat, DVM, MS, DACVS, Presenter: Sarah Malek, DVM, PhD, DACVS-SA, Presenter: Susan Schaefer, DVM, MS, DACVS.